AMOTHERM STEEL SB HI
SINGLE-COMPONENT SOLVENT-BASED VARNISH FOR FIRE-PROTECTION OF STEEL ELEMENTS
Technical features
- Once in place it looks like a normal varnish.
- It does not alter the aesthetics of the element
- It does not add weight to the geometry of the structural element to which it is apllied
- Can be applied indoors as well as in protected outdoor environments
Applications
Specifically designed for fire protection of structural steel elements in civil or industrial buildings. Suitable for internal and external conditions of use, after application of an anticorrosive primer and without the need for covering by any protective finish or in partially exposed or external conditions with a protective finish.
Drying time
- 6 – 12 hours at surface
- 24 – 48 hours at depth
Consumption
Defined on the basis of the structural element to be protected and the required technical performances.
Certifications
- Classified according to EN 13501 – 2
- Tested according to 13381 – 8
- European Technical Assessment ETA 21/0391
- EPD certification (environmental product declaration) according to UNI EN ISO 14025: 2010 – EN 15804: 2012
Packaging
5 – 20 Kg
Recommended treatments
- Indoor:
- 1x Amotherm Steel Primer Epoxy SB on galvanized structures / 1x Amotherm Steel Primer WB on black iron
- Amotherm Steel WB HI applied in multiple coats to reach prescribed quantity
- 1 x Amotherm Steel Top WB (optional for colored finishes)
Please contact the Amotherm Engineering and Assistance Service for detailed information on consumption: ingass@amonncolor.com
AMOTHERM STEEL SB HI
Riqualifica della resistenza al fuoco di elementi in acciaio fino a classe R 75 (travi e colonne, profili aperti e chiusi) in accordo alla norma EN 13381-8, attraverso fornitura e posa di pittura intumescente di tipo reattivo, monocomponente a base di polimeri acrilici in soluzione solvente e specifiche sostanze reattive (tipo AMOTHERM STEEL SB HI – ETA 19-0608 WF) di colore bianco e di consistenza tixotropica, applicata su fondo opportunamente preparato a spruzzo o rullo/pennello direttamente sulle superfici da proteggere, previo posa di primer compatibile adeguato (tipo AMOTHERM STEEL PRIMER ).
Il quantitativo di prodotto applicato verrà definito dal professionista antincendio attraverso un calcolo analitico o attraverso metodi semplificati in accordo all’Eurocodice EN 1993-1-2.
La pittura intumescente dovrà essere corredata di D.o.P. a garanzia dell’uso previsto di resistenza al fuoco per la protezione di strutture portanti in acciaio, oltre alla conformità applicativa di tipo Z1 e Z2 senza finitura e di tipo Y e X con finitura in accordo alla ETAG 018-2.
La posa in opera del rivestimento sarà realizzata secondo le prescrizioni del produttore.
…segue.
Per ricevere la scheda completa contatta il nostro servizio di assistenza tecnica ingass@amonncolor.com