fbpx
We use cookies to ensure you have a better experience on the site. We use third-party cookies to send you personalized promotional messages. For more information on cookies and their disabling, consult the Cookie Policy. If you continue browsing you consent to the use of cookies.
 

SOLVENT-BASED SOLUTION - UP TO R 60

Fire retrofit steel structures

 

Reference standard: EN 13381-8
Fire resistance: From R 15 to R 60 – Temp. Crit. from 350° to 750°
Type of protected elements: I/H (Open profiles) and closed profiles (square/circular sections)
C.E. marking: ETA 21/0391
Protective system: Amotherm Steel SB HI – solvent-based, intumescent, 1-component paint
Consumption: Depending on the critical collapse temperature of the single element
Technical reference document: ETA 21/0391
Surface preparation: Compatible primers: zinc phosphate/epoxyvinyl/alkyd/alkyd epoxypolyamines with phenolic resins. In case of galvanized Steel Amotherm Steel Primer WB (0.10 kg/m2)

 
 
amotherm - foto2 amotherm - foto1
amotherm - RENDER_STRUTTURE_NODO_PRIMER+VERNICE+FINITURA
 
Back to the list
 

SIMILAR PRODUCTS