STANDARD
Fire retrofit of ordinary and prestressed reinforced concrete structures
Reference standard: EN 13381-3:2002
Fire resistance: R 30 to R 240 – slabs/walls; from R 30 to R 120 beams/pillars
Type of protected elements: Beams/pillars and floors/walls
Protective system: Amotherm Brick WB – water-based, single-component paint
Consumption: Variable from 1,0 kg/m2 to 2,5 kg/m2
Technical reference document: Evaluation report CSI 2050 FR and CSI 2066 FR
Environmental certification: Indoor Air Comfort Gold®6.0 dated 02/2017 – EPD in accordance with ISO 14025 and EN 15804
Surface preparation: Amotherm Primer WB in the ratio of 0,10 kg/m2