TRANSPARENT INTUMESCENT CYCLE
Fire retrofit of wooden structures
Reference standard: EN 13381-7:2002
Fire resistance: From class R 15 and depending on the protected element
Type of protected elements: Beams/pillars and slabs/walls
Protective system: Amotherm Wood WSB – Mixed (water based base coat and solvent based top coat) intumescent, transparent, 1-component cycle for fire protection of wooden elements
Consumption: Variable from 0.36 kg/m2 to 0.67 kg/m2 + 0.10 kg/m2 of fnitura
Technical reference document: Evaluation report Fires JR 139-20 Nure 2
Environmental certification: Wood sanding to remove old paints or check compatibility. The preliminary use of non-flmogenic impregnating agents is allowed for the decoration or protection of wood.