SOLVENT-BASED TRANSPARENT CYCLE - CS1 d0
Fire retrofit of non structural wooden cladding elements
Reference standard: EN 13501-1
Reaction to fire: Class C s1 d0
Fire exposure: Wooden elements placed on the wall or ceiling or used for making furniture and furnishings
Type of Wood: Veneered wood, made of fireproof MDF support, ennobled with oak wood and assembled with phenolic glue. Total thickness of 17 mm.
Protective system: Solvent-based, transparent, two-component paint Amotherm Wood 300 SB
Consumption: From 0.24 kg/m2
Technical reference document: Classification report 379062 by I.G. (EN 13501-1)
Dimensions: Unlimited, thickness from 17 mm
Surface preparation: Sanding down to wooden surface to remove old paint or compatibility check. The preliminary use of non-film-forming impregnating treatments is permitted for the decoration or protection of wood.