WATER-BASED PIGMENTED CYCLE - Bs1 d0
Fire retrofit of non structural wooden cladding elements
Reference standard: EN 13501-1
Reaction to fire: Class B s1 d0
Fire exposure: Wooden elements placed on the wall or ceiling
Type of Wood: Wood and wood derivatives, neither containing air cavities nor assembled with thermoplastic glues
Protective system: White one-component paint Amotherm Wood WB and optional topcoat Amotherm Wood Top WB
Consumption: From 0.40 kg/m2 (Optional topcoat 0.10 kg/m2)
Technical reference document: Classification report 402533 by I.G. (EN 13501-1)
Dimensions: Unlimited, thickness from 4 mm
Surface preparation: Sanding down to wooden surface to remove old paint or compatibility check. The preliminary use of non-film-forming impregnating treatments is permitted for the decoration or protection of wood