WATER-BASED CYCLE - CFL,s1
FIRE PROTECTION REFURBISHMENT OF NON-STRUCTURAL WOODEN ELEMENTS
Reference standard: UNI EN 13501-1
Reaction to fire: CFL,s1 and Class 1 (Italy)
Flame impingement: Wooden elements placed on the floor
Wood typeac: Wood and wood derivatives, neither containing air cavities nor assembled with thermoplastic glues
Protective system: Amotherm Wood 640 WB, water-based, polyurethane fire-retardant
Consumption: 150g/sqm to 300g/sqm
Technical reference document: Classification report I.G. 417507 (EN 13501-1) and ministerial approval BL158PVI200025 (Ministry of the Interior, Rome – UNI 9796)
Dimensions: Unlimited, thickness from 4 mm
Surface preparation: Planing or sanding down to bare wood to remove old paint or other foreign materials. The preliminary use of non-film-forming impregnating treatments is allowed for the decoration or protection of wood.