NORMAL CLS CONCRETE 120mm - EI 90
Fire retrofit of existing CLS walls
Reference standard: EN 1364-1:2002
Fire resistance: EI 90
Flame impingement: Fire exposure on the protected side
Wall stratigraphy: Wall with a minimum thickness of 120 mm in normal single-chamber, exposed, cls concrete blocks
Environmental certification: Indoor Air Comfort Gold®6.0 dated 02/2017 – EPD in accordance with ISO 14025 and EN 15804
Protective system: Amotherm Brick WB – water-based, single-component paint
Consumption: 0.4 kg/m2
Technical reference document: Classification Report CSI 1788 FR
Technical file: Technical report IG n. 387592- FT n.04 / 2021
Height in the field of direct application: 4 m
Height extension: Not allowed
Extension in width: Admitted
Surface preparation: Amotherm Primer WB at a rate of 0.10 kg/m2