BOUND CORRUGATED SHEET METAL
Fire retrofit of existing slabs
Reference standard: EN 1365-2:2014
Fire resistance: REI 120
Flame impingement: Intrados
Slab height and stratigraphy: Htot 100 mm consisting of sheet metal type EGB 210D 0.8 mm (thick) and reinforced cls concrete casting 55 mm (height)
Protective system: Amotherm Steel WB – water-based, intumescent, one-component paint
Environmental certification: Indoor Air Comfort Gold®6.0 dated 02/2017 – EPD in accordance with ISO 14025 and EN 15804
Consumption:: 1,00 kg/m2
Technical reference document: Classification Report CSI 1950FR
Maximum permitted load: 270 kg/m2 on a calculation span of 2.95 m
Surface preparation: Amotherm Primer WB with consumption of 0.10 kg/m2
![amotherm - foto1](https://www.amonncolor.com/wp-content/uploads/2021/11/foto1.png)
![amotherm - foto2](https://www.amonncolor.com/wp-content/uploads/2021/11/foto2.png)
![amotherm - RIQUALIFICA AL FUOCO DI SOLAIO PIANO IN CLS E LAMIERA GRECATA COLLABORANTE-5_EN](https://www.amonncolor.com/wp-content/uploads/2021/12/RIQUALIFICA-AL-FUOCO-DI-SOLAIO-PIANO-IN-CLS-E-LAMIERA-GRECATA-COLLABORANTE-5_EN-1600x1600.jpg)