FIRE PROTECTION REFURBISHMENT OF PRESTRESSED HONEYCOMB SLABS
PROTECTION TO FIRE RETROFIT OF EXISTING SLABS
Reference standard: EN 1365- 2: 2014
Fire resistance: REI 180
Exposure to fire: Intrados
Height and stratigraphy of the slab: H= 210mm composed of a 160mm precast reinforced concrete slab. +50mm concrete hood
Protective system: Amotherm Brick WB – water-based, intumescent, monocomponent paint
Environmental certification: Indoor Air Comfort GOLD® 6.0 of 02/2017– EPD according to ISO 14025 and EN 15804
Consumption: 1,2 kg/m2
Technical reference document: Classification Report I.G.408505/4347 FR
Surface preparation: Amotherm Primer WB at 0.10 kg/m2